Name Theory_2279-804792-46_0
Workunit 1890557
Created 19 Apr 2019, 6:30:13 UTC
Sent 19 Apr 2019, 13:15:05 UTC
Report deadline 21 Apr 2019, 20:48:25 UTC
Received 19 Apr 2019, 13:20:07 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 3775
Run time 22 sec
CPU time 0 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 8.05 GFLOPS
Application version Theory Simulation v4.16 (vbox64_mt_mcore)
windows_x86_64
Peak working set size 10.61 MB
Peak swap size 6.51 MB
Peak disk usage 1.22 GB

Stderr output

<core_client_version>7.14.2</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code -2147467259 (0x80004005)</message>
<stderr_txt>
2019-04-19 06:15:48 (5636): Detected: vboxwrapper 26197
2019-04-19 06:15:48 (5636): Detected: BOINC client v7.7
2019-04-19 06:15:49 (5636): Detected: VirtualBox VboxManage Interface (Version: 6.0.4)
2019-04-19 06:15:49 (5636): Successfully copied 'init_data.xml' to the shared directory.
2019-04-19 06:15:49 (5636): Successfully copied 'cranky' to the shared directory.
2019-04-19 06:15:49 (5636): Successfully copied 'input' to the shared directory.
2019-04-19 06:15:50 (5636): Create VM. (boinc_760b58cdc23fa776, slot#1)
2019-04-19 06:15:51 (5636): Setting Memory Size for VM. (830MB)
2019-04-19 06:15:51 (5636): Setting CPU Count for VM. (2)
2019-04-19 06:15:52 (5636): Setting Chipset Options for VM.
2019-04-19 06:15:52 (5636): Setting Boot Options for VM.
2019-04-19 06:15:52 (5636): Setting Network Configuration for NAT.
2019-04-19 06:15:52 (5636): Enabling VM Network Access.
2019-04-19 06:15:53 (5636): Disabling USB Support for VM.
2019-04-19 06:15:53 (5636): Disabling COM Port Support for VM.
2019-04-19 06:15:53 (5636): Disabling LPT Port Support for VM.
2019-04-19 06:15:53 (5636): Disabling Audio Support for VM.
2019-04-19 06:15:54 (5636): Disabling Clipboard Support for VM.
2019-04-19 06:15:54 (5636): Disabling Drag and Drop Support for VM.
2019-04-19 06:15:54 (5636): Adding storage controller(s) to VM.
2019-04-19 06:15:54 (5636): Adding virtual disk drive to VM. (vm_image.vdi)
2019-04-19 06:15:55 (5636): Adding VirtualBox Guest Additions to VM.
2019-04-19 06:15:55 (5636): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2019-04-19 06:15:56 (5636): forwarding host port 55094 to guest port 80
2019-04-19 06:15:56 (5636): Enabling remote desktop for VM.
2019-04-19 06:15:56 (5636): Enabling shared directory for VM.
2019-04-19 06:15:57 (5636): Starting VM using VBoxManage interface. (boinc_760b58cdc23fa776, slot#1)
2019-04-19 06:16:02 (5636): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_760b58cdc23fa776" --type headless
Output:
Waiting for VM "boinc_760b58cdc23fa776" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2019-04-19 06:16:02 (5636): VM failed to start.
2019-04-19 06:16:02 (5636): Could not start 
2019-04-19 06:16:02 (5636): ERROR: VM failed to start
2019-04-19 06:16:02 (5636): Powering off VM.
2019-04-19 06:16:02 (5636): Deregistering VM. (boinc_760b58cdc23fa776, slot#1)
2019-04-19 06:16:02 (5636): Removing network bandwidth throttle group from VM.
2019-04-19 06:16:02 (5636): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:00.060053 main     Executable: C:\Program Files\Oracle\VirtualBox\VBoxSVC.exe
00:00:00.060054 main     Process ID: 6564
00:00:00.060054 main     Package type: WINDOWS_64BITS_GENERIC
00:00:00.130819          VirtualBox: object creation starts
00:00:00.131182          Home directory: 'C:\Users\Allan\.VirtualBox'
00:00:00.131350          Installed Drivers:
00:00:00.139048            C:\WINDOWS\system32\DRIVERS\VBoxNetLwf.sys (Version: 6.0.4.28413)
00:00:00.140553            C:\WINDOWS\system32\DRIVERS\VBoxUSBMon.sys (Version: 6.0.4.28413)
00:00:00.141405            C:\WINDOWS\system32\DRIVERS\VBoxDrv.sys (Version: 6.0.4.28413)
00:00:00.143571            C:\WINDOWS\system32\DRIVERS\VBoxNetAdp6.sys (Version: 6.0.4.28413)
00:00:00.153828          Loading settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:00.418551          HostDnsMonitor::updateInfo
00:00:00.418595          HostDnsMonitor: old information
00:00:00.418596            no server entries
00:00:00.418598            no domain set
00:00:00.418598            no search string entries
00:00:00.418599          HostDnsMonitor: new information
00:00:00.418599            server 1: 192.168.2.1
00:00:00.418601            no domain set
00:00:00.418601            no search string entries
00:00:00.539911          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.597706          VD: VDInit finished with VINF_SUCCESS
00:00:00.616830          OCI: Local config file 'C:\Users\Allan\.VirtualBox\oci_config' does not exist
00:00:00.616996          OCI: Original config file 'C:\Users\Allan\.oci\config' does not exist
00:00:00.616998          OCI: Reading profiles finished with status ERROR_SUCCESS
00:00:00.617006          ExtPack: Created cloud provider 'OCI' (hrc=ERROR_SUCCESS)
00:00:00.617044          VirtualBox: object created
00:00:01.022382          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_760b58cdc23fa776'}, preserve=false aResultDetail=0
00:00:01.820018          Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:02.089352          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:02.114336          Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:02.349464          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:02.632827          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:03.168260          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:03.466274          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:03.748350          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:04.009121          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:04.277463          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:04.542447          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:04.811020          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:05.075061          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:05.341728          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:05.604711          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:05.871871          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:06.136669          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:06.403651          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.406224          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.406468          Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.430340          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:06.707151          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.710311          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.710496          Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.861994          Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.052034          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:07.246949          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:07.514819          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:08.044679          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:08.308397          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:13.269496          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:13.525089          ERROR [COM]: aRC=VBOX_E_VM_ERROR (0x80bb0003) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={Failed to get a console object from the direct session (VBOX_E_INVALID_OBJECT_STATE)}, preserve=false aResultDetail=0
00:00:13.633240          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox" with version "1.16-windows"
00:00:13.892857          Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:19.063918 main     VirtualBox: object deletion starts
00:00:19.066271 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:19.066531 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 06:15:49 (5636): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2019-04-19T13:15:49.403000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Memory size: 8076 MByte
Memory available: 3999 MByte
Operating system: Windows 10
Operating system version: 10.0.17763

2019-04-19 06:15:49 (5636): 
Command: VBoxManage -q showvminfo "boinc_760b58cdc23fa776" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_760b58cdc23fa776'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp

2019-04-19 06:15:50 (5636): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: 0
Output:
UUID:           5bf7a55b-f946-49de-bb2e-62c1ee69134f
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\slots\1\vm_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   1251 MBytes
Encryption:     disabled

2019-04-19 06:15:50 (5636): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: 0
Output:
UUID:           5bf7a55b-f946-49de-bb2e-62c1ee69134f
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\slots\1\vm_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   1251 MBytes
Encryption:     disabled

2019-04-19 06:15:50 (5636): 
Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: 0
Output:

2019-04-19 06:15:50 (5636): 
Command: VBoxManage -q createvm --name "boinc_760b58cdc23fa776" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_760b58cdc23fa776' is created and registered.
UUID: 8dbe59df-b4b8-4294-bb4d-f825298c29ed
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_760b58cdc23fa776\boinc_760b58cdc23fa776.vbox'

2019-04-19 06:15:51 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --description "Theory_2279-804792-46_0" 
Exit Code: 0
Output:

2019-04-19 06:15:51 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --memory 830 
Exit Code: 0
Output:

2019-04-19 06:15:52 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --cpus 2 
Exit Code: 0
Output:

2019-04-19 06:15:52 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --acpi on --ioapic on 
Exit Code: 0
Output:

2019-04-19 06:15:52 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2019-04-19 06:15:52 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2019-04-19 06:15:53 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --cableconnected1 on 
Exit Code: 0
Output:

2019-04-19 06:15:53 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --usb off 
Exit Code: 0
Output:

2019-04-19 06:15:53 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --uart1 off --uart2 off 
Exit Code: 0
Output:

2019-04-19 06:15:53 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2019-04-19 06:15:54 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --audio none 
Exit Code: 0
Output:

2019-04-19 06:15:54 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --clipboard disabled 
Exit Code: 0
Output:

2019-04-19 06:15:54 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --draganddrop disabled 
Exit Code: 0
Output:

2019-04-19 06:15:54 (5636): 
Command: VBoxManage -q storagectl "boinc_760b58cdc23fa776" --name "Hard Disk Controller" --add "ide" --controller "PIIX4" 
Exit Code: 0
Output:

2019-04-19 06:15:55 (5636): 
Command: VBoxManage -q storageattach "boinc_760b58cdc23fa776" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --setuuid "" --medium "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: 0
Output:

2019-04-19 06:15:55 (5636): 
Command: VBoxManage -q storageattach "boinc_760b58cdc23fa776" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2019-04-19 06:15:56 (5636): 
Command: VBoxManage -q bandwidthctl "boinc_760b58cdc23fa776" add "boinc_760b58cdc23fa776_net" --type network --limit 1024G 
Exit Code: 0
Output:

2019-04-19 06:15:56 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --natpf1 ",tcp,127.0.0.1,55094,,80" 
Exit Code: 0
Output:

2019-04-19 06:15:56 (5636): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:      6.0.4
Revision:     128413
Edition:      
Description:  USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe.
VRDE Module:  VBoxVRDP
Usable:       true 
Why unusable: 

2019-04-19 06:15:56 (5636): 
Command: VBoxManage -q modifyvm "boinc_760b58cdc23fa776" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 55095 
Exit Code: 0
Output:

2019-04-19 06:15:57 (5636): 
Command: VBoxManage -q sharedfolder add "boinc_760b58cdc23fa776" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2019-04-19 06:16:02 (5636): 
Command: VBoxManage -q startvm "boinc_760b58cdc23fa776" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_760b58cdc23fa776" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2019-04-19 06:16:02 (5636): 
Command: VBoxManage -q snapshot "boinc_760b58cdc23fa776" list 
Exit Code: -2135228413
Output:
VBoxManage.exe: error: Failed to get a console object from the direct session (VBOX_E_INVALID_OBJECT_STATE)
VBoxManage.exe: error: Details: code VBOX_E_VM_ERROR (0x80bb0003), component MachineWrap, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "LockMachine(a->session, LockType_Shared)" at line 331 of file VBoxManageSnapshot.cpp

2019-04-19 06:16:02 (5636): 
Command: VBoxManage -q bandwidthctl "boinc_760b58cdc23fa776" remove "boinc_760b58cdc23fa776_net" 
Exit Code: 0
Output:

2019-04-19 06:16:02 (5636): 
Command: VBoxManage -q unregistervm "boinc_760b58cdc23fa776" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

06:16:07 (5636): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 CERN