Name | CMS_2125141_1684826809.190990_0 |
Workunit | 2307996 |
Created | 23 May 2023, 7:26:54 UTC |
Sent | 24 May 2023, 23:51:58 UTC |
Report deadline | 31 May 2023, 23:51:58 UTC |
Received | 25 May 2023, 0:27:57 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 4901 |
Run time | 4 min 10 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 10.02 GFLOPS |
Application version | CMS Simulation v60.70 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 10.29 MB |
Peak swap size | 6.24 MB |
Peak disk usage | 40.30 KB |
<core_client_version>7.20.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2023-05-25 10:21:50 (31568): Detected: vboxwrapper 26206 2023-05-25 10:21:50 (31568): Detected: BOINC client v7.20.2 2023-05-25 10:22:01 (31568): Detected: VirtualBox VboxManage Interface (Version: 6.1.34) 2023-05-25 10:22:13 (31568): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2023-05-25 10:22:13 (31568): Successfully copied 'init_data.xml' to the shared directory. 2023-05-25 10:22:25 (31568): Create VM. (boinc_e440578c12bd322c, slot#60) 2023-05-25 10:22:37 (31568): Setting Memory Size for VM. (2792MB) 2023-05-25 10:22:43 (31568): Setting CPU Count for VM. (2) 2023-05-25 10:22:49 (31568): Setting Chipset Options for VM. 2023-05-25 10:22:55 (31568): Setting Graphics Controller Options for VM. 2023-05-25 10:23:01 (31568): Setting Boot Options for VM. 2023-05-25 10:23:07 (31568): Setting Network Configuration for NAT. 2023-05-25 10:23:18 (31568): Enabling VM Network Access. 2023-05-25 10:23:23 (31568): Disabling USB Support for VM. 2023-05-25 10:23:29 (31568): Disabling COM Port Support for VM. 2023-05-25 10:23:40 (31568): Disabling LPT Port Support for VM. 2023-05-25 10:23:46 (31568): Disabling Audio Support for VM. 2023-05-25 10:23:52 (31568): Disabling Clipboard Support for VM. 2023-05-25 10:23:58 (31568): Disabling Drag and Drop Support for VM. 2023-05-25 10:24:04 (31568): Adding storage controller(s) to VM. 2023-05-25 10:24:10 (31568): Adding virtual disk drive to VM. (CMS_2022_09_07.vdi) 2023-05-25 10:24:33 (31568): Adding VirtualBox Guest Additions to VM. 2023-05-25 10:24:39 (31568): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2023-05-25 10:24:45 (31568): forwarding host port 50544 to guest port 80 2023-05-25 10:24:51 (31568): Enabling remote desktop for VM. 2023-05-25 10:24:57 (31568): Required extension pack not installed, remote desktop not enabled. 2023-05-25 10:24:57 (31568): Enabling shared directory for VM. 2023-05-25 10:25:09 (31568): Starting VM using VBoxManage interface. (boinc_e440578c12bd322c, slot#60) 2023-05-25 10:25:20 (31568): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_e440578c12bd322c" --type headless Output: Waiting for VM "boinc_e440578c12bd322c" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2023-05-25 10:25:20 (31568): VM failed to start. 2023-05-25 10:25:20 (31568): Could not start 2023-05-25 10:25:20 (31568): ERROR: VM failed to start 2023-05-25 10:25:20 (31568): Powering off VM. 2023-05-25 10:25:20 (31568): Deregistering VM. (boinc_e440578c12bd322c, slot#60) 2023-05-25 10:25:26 (31568): Removing network bandwidth throttle group from VM. 2023-05-25 10:25:32 (31568): Removing VM from VirtualBox. Hypervisor System Log: 00:00:00.003859 main VirtualBox COM Server 6.1.34 r150636 win.amd64 (Mar 23 2022 00:36:21) release log 00:00:00.003862 main Log opened 2023-05-25T00:25:32.272492600Z 00:00:00.003863 main Build Type: release 00:00:00.003868 main OS Product: Windows 10 00:00:00.003869 main OS Release: 10.0.19045 00:00:00.003870 main OS Service Pack: 00:00:00.037080 main DMI Product Name: MS-7C60 00:00:00.064534 main DMI Product Version: 1.0 00:00:00.064551 main Firmware type: UEFI 00:00:00.065028 main Secure Boot: VERR_PRIVILEGE_NOT_HELD 00:00:00.065047 main Host RAM: 32656MB (31.8GB) total, 16561MB (16.1GB) available 00:00:00.065051 main Executable: C:\Program Files\Oracle\VirtualBox\VBoxSVC.exe 00:00:00.065052 main Process ID: 14484 00:00:00.065053 main Package type: WINDOWS_64BITS_GENERIC 00:00:00.074900 VirtualBox: object creation starts 00:00:00.075134 Home directory: 'C:\Users\peter\.VirtualBox' 00:00:00.075254 Installed Drivers: 00:00:00.081406 C:\Windows\system32\DRIVERS\VBoxNetLwf.sys (Version: 6.1.34.636) 00:00:00.081920 C:\Windows\system32\DRIVERS\VBoxUSBMon.sys (Version: 6.1.34.636) 00:00:00.082191 C:\Windows\system32\DRIVERS\VBoxSup.sys (Version: 6.1.34.636) 00:00:00.082679 C:\Windows\system32\DRIVERS\VBoxNetAdp6.sys (Version: 6.1.34.636) 00:00:00.085390 Loading settings file "C:\Users\peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:00.087110 usbLibGetDevices: Starting USB device enumeration 00:00:00.371601 Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#ROOT_HUB30#7&1905af5d&0&0#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 6 00:00:00.371884 Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#ROOT_HUB30#7&220a37a1&0&0#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:00.376960 usbLibGetDevices: Found 5 USB devices, 0 captured 00:00:00.377115 USB: Unknown USB device detected (idVendor: 0x1462, idProduct: 0x7c60) 00:00:00.377145 USB: Unknown USB device detected (idVendor: 0x8087, idProduct: 0x0029) 00:00:00.561096 HostDnsMonitor: initializing 00:00:00.610120 HostDnsMonitor: updating information 00:00:00.610147 HostDnsMonitor: old information 00:00:00.610148 no server entries 00:00:00.610149 no domain set 00:00:00.610150 no search string entries 00:00:00.610151 HostDnsMonitor: new information 00:00:00.610151 server 1: 192.168.0.1 00:00:00.610152 domain: modem 00:00:00.610153 no search string entries 00:00:00.751115 SUPR0QueryVTCaps -> VERR_SVM_DISABLED 00:00:00.751621 VD: VDInit finished with VINF_SUCCESS 00:00:00.752849 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Runtime error opening 'C:\ProgramData\BOINC\slots\1\boinc_e05764547778aa44\boinc_e05764547778aa44.vbox' for reading: -103 (Path not found.). 00:00:00.752912 F:\tinderbox\win-6.1\src\VBox\Main\src-server\MachineImpl.cpp[754] (long __cdecl Machine::i_registeredInit(void))}, preserve=false aResultDetail=0 00:00:00.754172 Loading settings file "C:\ProgramData\BOINC\slots\60\boinc_e440578c12bd322c\boinc_e440578c12bd322c.vbox" with version "1.16-windows" 00:00:00.755068 VirtualBox: object created 00:00:00.825364 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:00.826316 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:00.826453 Saving settings file "C:\Users\peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.849907 main VirtualBox: object deletion starts 00:00:05.850743 main HostDnsMonitor: shutting down ... 00:00:05.850784 main HostDnsMonitor: shut down 00:00:05.852435 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:05.852658 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: pper 3990X 64-Core Processor Processor#118 speed: unknown Processor#118 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#119 speed: unknown Processor#119 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#120 speed: unknown Processor#120 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#121 speed: unknown Processor#121 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#122 speed: unknown Processor#122 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#123 speed: unknown Processor#123 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#124 speed: unknown Processor#124 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#125 speed: unknown Processor#125 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#126 speed: unknown Processor#126 description: AMD Ryzen Threadripper 3990X 64-Core Processor Processor#127 speed: unknown Processor#127 description: AMD Ryzen Threadripper 3990X 64-Core Processor Memory size: 32656 MByte Memory available: 16591 MByte Operating system: Windows 10 Operating system version: 10.0.19045 2023-05-25 10:22:19 (31568): Command: VBoxManage -q showvminfo "boinc_e440578c12bd322c" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_e440578c12bd322c' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2733 of file VBoxManageInfo.cpp 2023-05-25 10:22:25 (31568): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\60/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\60\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2023-05-25 10:22:31 (31568): Command: VBoxManage -q createvm --name "boinc_e440578c12bd322c" --basefolder "C:\ProgramData\BOINC\slots\60" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_e440578c12bd322c' is created and registered. UUID: dd4402a7-c3aa-45c1-9e8a-2ed73059862f Settings file: 'C:\ProgramData\BOINC\slots\60\boinc_e440578c12bd322c\boinc_e440578c12bd322c.vbox' 2023-05-25 10:22:37 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --description "CMS_2125141_1684826809.190990_0" Exit Code: 0 Output: 2023-05-25 10:22:43 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --memory 2792 Exit Code: 0 Output: 2023-05-25 10:22:49 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --cpus 2 Exit Code: 0 Output: 2023-05-25 10:22:55 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2023-05-25 10:23:01 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2023-05-25 10:23:07 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2023-05-25 10:23:18 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2023-05-25 10:23:23 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --cableconnected1 on Exit Code: 0 Output: 2023-05-25 10:23:29 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --usb off Exit Code: 0 Output: 2023-05-25 10:23:35 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --uart1 off --uart2 off Exit Code: 0 Output: 2023-05-25 10:23:46 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --lpt1 off --lpt2 off Exit Code: 0 Output: 2023-05-25 10:23:52 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --audio none Exit Code: 0 Output: 2023-05-25 10:23:58 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --clipboard disabled Exit Code: 0 Output: 2023-05-25 10:24:04 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --draganddrop disabled Exit Code: 0 Output: 2023-05-25 10:24:10 (31568): Command: VBoxManage -q storagectl "boinc_e440578c12bd322c" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2023-05-25 10:24:16 (31568): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: UUID: 8fb925ef-3497-4bfb-88e3-bbab2930787f Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3854 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2023-05-25 10:24:22 (31568): Command: VBoxManage -q storageattach "boinc_e440578c12bd322c" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2023-05-25 10:24:28 (31568): Command: VBoxManage -q storageattach "boinc_e440578c12bd322c" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2023-05-25 10:24:33 (31568): Command: VBoxManage -q storageattach "boinc_e440578c12bd322c" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2023-05-25 10:24:39 (31568): Command: VBoxManage -q storageattach "boinc_e440578c12bd322c" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2023-05-25 10:24:45 (31568): Command: VBoxManage -q bandwidthctl "boinc_e440578c12bd322c" add "boinc_e440578c12bd322c_net" --type network --limit 1024G Exit Code: 0 Output: 2023-05-25 10:24:51 (31568): Command: VBoxManage -q modifyvm "boinc_e440578c12bd322c" --natpf1 ",tcp,127.0.0.1,50544,,80" Exit Code: 0 Output: 2023-05-25 10:24:57 (31568): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2023-05-25 10:25:03 (31568): Command: VBoxManage -q sharedfolder add "boinc_e440578c12bd322c" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\60/shared" Exit Code: 0 Output: 2023-05-25 10:25:20 (31568): Command: VBoxManage -q startvm "boinc_e440578c12bd322c" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_e440578c12bd322c" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2023-05-25 10:25:26 (31568): Command: VBoxManage -q snapshot "boinc_e440578c12bd322c" list Exit Code: -108 Output: This machine does not have any snapshots 2023-05-25 10:25:32 (31568): Command: VBoxManage -q bandwidthctl "boinc_e440578c12bd322c" remove "boinc_e440578c12bd322c_net" Exit Code: 0 Output: 2023-05-25 10:25:38 (31568): Command: VBoxManage -q unregistervm "boinc_e440578c12bd322c" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 10:25:53 (31568): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN