Name | CMS_2483155_1701193848.587105_0 |
Workunit | 2364778 |
Created | 28 Nov 2023, 17:50:50 UTC |
Sent | 30 Nov 2023, 13:56:04 UTC |
Report deadline | 7 Dec 2023, 13:56:04 UTC |
Received | 30 Nov 2023, 14:01:48 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 5043 |
Run time | 23 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.81 GFLOPS |
Application version | CMS Simulation v60.70 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 10.59 MB |
Peak swap size | 5.20 MB |
Peak disk usage | 0.01 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2023-11-30 09:00:04 (17424): Detected: vboxwrapper 26206 2023-11-30 09:00:04 (17424): Detected: BOINC client v7.24.1 2023-11-30 09:00:05 (17424): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2023-11-30 09:00:05 (17424): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2023-11-30 09:00:05 (17424): Successfully copied 'init_data.xml' to the shared directory. 2023-11-30 09:00:06 (17424): Create VM. (boinc_0472ddf0893f57fa, slot#7) 2023-11-30 09:00:06 (17424): Setting Memory Size for VM. (1896MB) 2023-11-30 09:00:07 (17424): Setting CPU Count for VM. (1) 2023-11-30 09:00:07 (17424): Setting Chipset Options for VM. 2023-11-30 09:00:07 (17424): Setting Graphics Controller Options for VM. 2023-11-30 09:00:07 (17424): Setting Boot Options for VM. 2023-11-30 09:00:08 (17424): Setting Network Configuration for NAT. 2023-11-30 09:00:08 (17424): Enabling VM Network Access. 2023-11-30 09:00:08 (17424): Disabling USB Support for VM. 2023-11-30 09:00:09 (17424): Disabling COM Port Support for VM. 2023-11-30 09:00:09 (17424): Disabling LPT Port Support for VM. 2023-11-30 09:00:09 (17424): Disabling Audio Support for VM. 2023-11-30 09:00:10 (17424): Disabling Clipboard Support for VM. 2023-11-30 09:00:10 (17424): Disabling Drag and Drop Support for VM. 2023-11-30 09:00:10 (17424): Adding storage controller(s) to VM. 2023-11-30 09:00:10 (17424): Adding virtual disk drive to VM. (CMS_2022_09_07.vdi) 2023-11-30 09:00:14 (17424): Adding VirtualBox Guest Additions to VM. 2023-11-30 09:00:14 (17424): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2023-11-30 09:00:14 (17424): forwarding host port 49685 to guest port 80 2023-11-30 09:00:14 (17424): Enabling remote desktop for VM. 2023-11-30 09:00:15 (17424): Required extension pack not installed, remote desktop not enabled. 2023-11-30 09:00:15 (17424): Enabling shared directory for VM. 2023-11-30 09:00:15 (17424): Starting VM using VBoxManage interface. (boinc_0472ddf0893f57fa, slot#7) 2023-11-30 09:00:20 (17424): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_0472ddf0893f57fa" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_0472ddf0893f57fa" to power on... 2023-11-30 09:00:20 (17424): VM failed to start. 2023-11-30 09:00:20 (17424): Could not start 2023-11-30 09:00:20 (17424): ERROR: VM failed to start 2023-11-30 09:00:20 (17424): Powering off VM. 2023-11-30 09:00:20 (17424): Deregistering VM. (boinc_0472ddf0893f57fa, slot#7) 2023-11-30 09:00:20 (17424): Removing network bandwidth throttle group from VM. 2023-11-30 09:00:21 (17424): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.965498 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" with version "1.19-windows" 00:00:08.968097 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" 00:00:09.230896 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.233110 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.234339 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.234447 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.234533 Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.240663 Finished saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" 00:00:09.241601 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.241780 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.241955 Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.247096 Finished saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" 00:00:09.247593 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" with version "1.19-windows" 00:00:09.249217 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" 00:00:09.518491 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.521006 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" with version "1.19-windows" 00:00:09.523368 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" 00:00:09.803283 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.807292 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" with version "1.19-windows" 00:00:09.812233 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" 00:00:10.422339 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.425716 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" with version "1.19-windows" 00:00:10.427989 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" 00:00:10.680033 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.685916 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.701052 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.701123 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.707202 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.958961 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.964517 Launched VM: 1108531456 pid: 21640 (0x5488) frontend: headless name: boinc_0472ddf0893f57fa 00:00:15.802590 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" with version "1.19-windows" 00:00:15.804856 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox" 00:00:15.883509 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.884943 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.984734 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.308616 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.310272 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.310517 Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.319251 Finished saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" 00:00:16.319498 Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.323450 Finished saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" 00:00:16.325401 DeleteVM Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.329696 DeleteVM Finished saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" 00:00:21.380593 main VirtualBox: object deletion starts 00:00:21.382643 main HostDnsMonitor: shutting down ... 00:00:21.382820 main HostDnsMonitor: shut down 00:00:21.388788 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:21.389504 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: s\7/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2023-11-30 09:00:06 (17424): Command: VBoxManage -q createvm --name "boinc_0472ddf0893f57fa" --basefolder "C:\ProgramData\BOINC\slots\7" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_0472ddf0893f57fa' is created and registered. UUID: 7fc6cace-9d9d-4ee3-a741-6bec9374ef4d Settings file: 'C:\ProgramData\BOINC\slots\7\boinc_0472ddf0893f57fa\boinc_0472ddf0893f57fa.vbox' 2023-11-30 09:00:06 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --description "CMS_2483155_1701193848.587105_0" Exit Code: 0 Output: 2023-11-30 09:00:07 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --memory 1896 Exit Code: 0 Output: 2023-11-30 09:00:07 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --cpus 1 Exit Code: 0 Output: 2023-11-30 09:00:07 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2023-11-30 09:00:07 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2023-11-30 09:00:08 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2023-11-30 09:00:08 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2023-11-30 09:00:08 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --cableconnected1 on Exit Code: 0 Output: 2023-11-30 09:00:09 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --usb off Exit Code: 0 Output: 2023-11-30 09:00:09 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --uart1 off --uart2 off Exit Code: 0 Output: 2023-11-30 09:00:09 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --lpt1 off --lpt2 off Exit Code: 0 Output: 2023-11-30 09:00:10 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2023-11-30 09:00:10 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --clipboard disabled Exit Code: 0 Output: 2023-11-30 09:00:10 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --draganddrop disabled Exit Code: 0 Output: 2023-11-30 09:00:10 (17424): Command: VBoxManage -q storagectl "boinc_0472ddf0893f57fa" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2023-11-30 09:00:11 (17424): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: UUID: 8fb925ef-3497-4bfb-88e3-bbab2930787f Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3854 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2023-11-30 09:00:11 (17424): Command: VBoxManage -q storageattach "boinc_0472ddf0893f57fa" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2023-11-30 09:00:11 (17424): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2023-11-30 09:00:13 (17424): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: UUID: 8fb925ef-3497-4bfb-88e3-bbab2930787f Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3854 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2023-11-30 09:00:13 (17424): Command: VBoxManage -q storageattach "boinc_0472ddf0893f57fa" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2023-11-30 09:00:13 (17424): Command: VBoxManage -q storageattach "boinc_0472ddf0893f57fa" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2023-11-30 09:00:14 (17424): Command: VBoxManage -q storageattach "boinc_0472ddf0893f57fa" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2023-11-30 09:00:14 (17424): Command: VBoxManage -q storageattach "boinc_0472ddf0893f57fa" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2023-11-30 09:00:14 (17424): Command: VBoxManage -q bandwidthctl "boinc_0472ddf0893f57fa" add "boinc_0472ddf0893f57fa_net" --type network --limit 1024G Exit Code: 0 Output: 2023-11-30 09:00:14 (17424): Command: VBoxManage -q modifyvm "boinc_0472ddf0893f57fa" --natpf1 ",tcp,127.0.0.1,49685,,80" Exit Code: 0 Output: 2023-11-30 09:00:15 (17424): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2023-11-30 09:00:15 (17424): Command: VBoxManage -q sharedfolder add "boinc_0472ddf0893f57fa" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\7/shared" Exit Code: 0 Output: 2023-11-30 09:00:20 (17424): Command: VBoxManage -q startvm "boinc_0472ddf0893f57fa" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_0472ddf0893f57fa" to power on... 2023-11-30 09:00:20 (17424): Command: VBoxManage -q snapshot "boinc_0472ddf0893f57fa" list Exit Code: -108 Output: This machine does not have any snapshots 2023-11-30 09:00:21 (17424): Command: VBoxManage -q bandwidthctl "boinc_0472ddf0893f57fa" remove "boinc_0472ddf0893f57fa_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2023-11-30 09:00:21 (17424): Command: VBoxManage -q unregistervm "boinc_0472ddf0893f57fa" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 09:00:26 (17424): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN