Name CMS_449734_1705880488.463245_0
Workunit 2378416
Created 21 Jan 2024, 23:41:30 UTC
Sent 23 Jan 2024, 11:12:48 UTC
Report deadline 30 Jan 2024, 11:12:48 UTC
Received 23 Jan 2024, 11:26:03 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 2646
Run time 30 sec
CPU time 0 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 15.56 GFLOPS
Application version CMS Simulation v60.70 (vbox64_mt_mcore_cms)
windows_x86_64
Peak working set size 10.00 MB
Peak swap size 2.11 MB
Peak disk usage 8.79 KB

Stderr output

<core_client_version>7.16.5</core_client_version>
<![CDATA[
<message>
Niet nader omschreven fout
 (0x80004005) - exit code -2147467259 (0x80004005)</message>
<stderr_txt>
2024-01-23 12:24:07 (14248): Detected: vboxwrapper 26206
2024-01-23 12:24:07 (14248): Detected: BOINC client v7.16.5
2024-01-23 12:24:10 (14248): Detected: VirtualBox VboxManage Interface (Version: 7.0.8)
2024-01-23 12:24:11 (14248): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-01-23 12:24:11 (14248): Successfully copied 'init_data.xml' to the shared directory.
2024-01-23 12:24:11 (14248): Create VM. (boinc_0c51513c1bf91132, slot#8)
2024-01-23 12:24:12 (14248): Setting Memory Size for VM. (4584MB)
2024-01-23 12:24:12 (14248): Setting CPU Count for VM. (4)
2024-01-23 12:24:12 (14248): Setting Chipset Options for VM.
2024-01-23 12:24:12 (14248): Setting Graphics Controller Options for VM.
2024-01-23 12:24:13 (14248): Setting Boot Options for VM.
2024-01-23 12:24:13 (14248): Setting Network Configuration for NAT.
2024-01-23 12:24:13 (14248): Enabling VM Network Access.
2024-01-23 12:24:14 (14248): Disabling USB Support for VM.
2024-01-23 12:24:14 (14248): Disabling COM Port Support for VM.
2024-01-23 12:24:14 (14248): Disabling LPT Port Support for VM.
2024-01-23 12:24:14 (14248): Disabling Audio Support for VM.
2024-01-23 12:24:15 (14248): Disabling Clipboard Support for VM.
2024-01-23 12:24:15 (14248): Disabling Drag and Drop Support for VM.
2024-01-23 12:24:15 (14248): Adding storage controller(s) to VM.
2024-01-23 12:24:15 (14248): Adding virtual disk drive to VM. (CMS_2022_09_07.vdi)
2024-01-23 12:24:18 (14248): Adding VirtualBox Guest Additions to VM.
2024-01-23 12:24:19 (14248): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2024-01-23 12:24:19 (14248): forwarding host port 54810 to guest port 80
2024-01-23 12:24:19 (14248): Enabling remote desktop for VM.
2024-01-23 12:24:20 (14248): Enabling shared directory for VM.
2024-01-23 12:24:22 (14248): Starting VM using VBoxManage interface. (boinc_0c51513c1bf91132, slot#8)
2024-01-23 12:24:30 (14248): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_0c51513c1bf91132" --type headless
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_0c51513c1bf91132" to power on...

2024-01-23 12:24:30 (14248): VM failed to start.
2024-01-23 12:24:30 (14248): Could not start 
2024-01-23 12:24:30 (14248): ERROR: VM failed to start
2024-01-23 12:24:30 (14248): Powering off VM.
2024-01-23 12:24:30 (14248): Deregistering VM. (boinc_0c51513c1bf91132, slot#8)
2024-01-23 12:24:30 (14248): Removing network bandwidth throttle group from VM.
2024-01-23 12:24:30 (14248): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.242233          Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:09.695900          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.696642          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.749159          Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.783038          Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:09.783720          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:09.845579          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:09.970368          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:10.000935          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:10.219117          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.220040          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:10.312969          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:10.313297          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.316852          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:10.355648          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:10.356327          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:10.393692          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:10.490059          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.641281          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.641641          Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.681802          Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:10.682370          Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.711767          Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:10.712319          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:10.741775          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:11.010553          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:11.070610          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:11.280771          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:11.299074          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:11.855883          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:11.889073          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:12.096998          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:12.169004          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:12.739190          ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0
00:00:12.746332          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:12.746432          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:13.335910          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:13.704161          Launched VM: 1433524256 pid: 4732 (0x127c) frontend: headless name: boinc_0c51513c1bf91132
00:00:21.867996          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox" with version "1.19-windows"
00:00:22.049993          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox"
00:00:22.161149          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:22.509541          Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:22.538155          Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:22.538347          Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:22.570840          Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:22.572270 DeleteVM Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:22.607380 DeleteVM Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml"
00:00:27.627733 main     VirtualBox: object deletion starts
00:00:27.629084 main     HostDnsMonitor: shutting down ...
00:00:27.629116 main     HostDnsMonitor: shut down
00:00:27.631396 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:27.631742 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

vm --name "boinc_0c51513c1bf91132" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_0c51513c1bf91132' is created and registered.
UUID: 9a935fdc-fe56-464c-a0e7-eee49512e9f4
Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_0c51513c1bf91132\boinc_0c51513c1bf91132.vbox'

2024-01-23 12:24:12 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --description "CMS_449734_1705880488.463245_0" 
Exit Code: 0
Output:

2024-01-23 12:24:12 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --memory 4584 
Exit Code: 0
Output:

2024-01-23 12:24:12 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --cpus 4 
Exit Code: 0
Output:

2024-01-23 12:24:12 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2024-01-23 12:24:13 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2024-01-23 12:24:13 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2024-01-23 12:24:13 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2024-01-23 12:24:14 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --cableconnected1 on 
Exit Code: 0
Output:

2024-01-23 12:24:14 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --usb off 
Exit Code: 0
Output:

2024-01-23 12:24:14 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --uart1 off --uart2 off 
Exit Code: 0
Output:

2024-01-23 12:24:14 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2024-01-23 12:24:15 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2024-01-23 12:24:15 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --clipboard disabled 
Exit Code: 0
Output:

2024-01-23 12:24:15 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --draganddrop disabled 
Exit Code: 0
Output:

2024-01-23 12:24:15 (14248): 
Command: VBoxManage -q storagectl "boinc_0c51513c1bf91132" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2024-01-23 12:24:16 (14248): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" 
Exit Code: 0
Output:
UUID:           8fb925ef-3497-4bfb-88e3-bbab2930787f
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3854 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-01-23 12:24:16 (14248): 
Command: VBoxManage -q storageattach "boinc_0c51513c1bf91132" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2024-01-23 12:24:16 (14248): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" 
Exit Code: 0
Output:

2024-01-23 12:24:18 (14248): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" 
Exit Code: 0
Output:
UUID:           8fb925ef-3497-4bfb-88e3-bbab2930787f
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3854 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-01-23 12:24:18 (14248): 
Command: VBoxManage -q storageattach "boinc_0c51513c1bf91132" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" 
Exit Code: 0
Output:

2024-01-23 12:24:18 (14248): 
Command: VBoxManage -q storageattach "boinc_0c51513c1bf91132" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2024-01-23 12:24:18 (14248): 
Command: VBoxManage -q storageattach "boinc_0c51513c1bf91132" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" 
Exit Code: 0
Output:

2024-01-23 12:24:19 (14248): 
Command: VBoxManage -q storageattach "boinc_0c51513c1bf91132" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2024-01-23 12:24:19 (14248): 
Command: VBoxManage -q bandwidthctl "boinc_0c51513c1bf91132" add "boinc_0c51513c1bf91132_net" --type network --limit 1024G 
Exit Code: 0
Output:

2024-01-23 12:24:19 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --natpf1 ",tcp,127.0.0.1,54810,,80" 
Exit Code: 0
Output:

2024-01-23 12:24:20 (14248): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        7.0.8
Revision:       156879
Edition:        
Description:    Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption.
VRDE Module:    VBoxVRDP
Crypto Module:  VBoxPuelCrypto
Usable:         true
Why unusable:   

2024-01-23 12:24:20 (14248): 
Command: VBoxManage -q modifyvm "boinc_0c51513c1bf91132" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 54811 
Exit Code: 0
Output:

2024-01-23 12:24:20 (14248): 
Command: VBoxManage -q sharedfolder add "boinc_0c51513c1bf91132" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared"
Exit Code: 0
Output:

2024-01-23 12:24:30 (14248): 
Command: VBoxManage -q startvm "boinc_0c51513c1bf91132" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_0c51513c1bf91132" to power on...

2024-01-23 12:24:30 (14248): 
Command: VBoxManage -q snapshot "boinc_0c51513c1bf91132" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2024-01-23 12:24:30 (14248): 
Command: VBoxManage -q bandwidthctl "boinc_0c51513c1bf91132" remove "boinc_0c51513c1bf91132_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2024-01-23 12:24:31 (14248): 
Command: VBoxManage -q unregistervm "boinc_0c51513c1bf91132" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

12:24:36 (14248): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 CERN