Name | CMS_2345296_1707782444.511479_0 |
Workunit | 2388542 |
Created | 13 Feb 2024, 0:00:46 UTC |
Sent | 13 Feb 2024, 15:58:09 UTC |
Report deadline | 20 Feb 2024, 15:58:09 UTC |
Received | 13 Feb 2024, 16:08:44 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 2646 |
Run time | 32 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 15.49 GFLOPS |
Application version | CMS Simulation v60.70 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 9.42 MB |
Peak swap size | 2.08 MB |
Peak disk usage | 8.79 KB |
<core_client_version>7.16.5</core_client_version> <![CDATA[ <message> Niet nader omschreven fout (0x80004005) - exit code -2147467259 (0x80004005)</message> <stderr_txt> 2024-02-13 17:06:41 (19544): Detected: vboxwrapper 26206 2024-02-13 17:06:41 (19544): Detected: BOINC client v7.16.5 2024-02-13 17:06:44 (19544): Detected: VirtualBox VboxManage Interface (Version: 7.0.8) 2024-02-13 17:06:45 (19544): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-02-13 17:06:45 (19544): Successfully copied 'init_data.xml' to the shared directory. 2024-02-13 17:06:45 (19544): Create VM. (boinc_a0b23db1659f4505, slot#8) 2024-02-13 17:06:46 (19544): Setting Memory Size for VM. (4584MB) 2024-02-13 17:06:46 (19544): Setting CPU Count for VM. (4) 2024-02-13 17:06:47 (19544): Setting Chipset Options for VM. 2024-02-13 17:06:47 (19544): Setting Graphics Controller Options for VM. 2024-02-13 17:06:47 (19544): Setting Boot Options for VM. 2024-02-13 17:06:48 (19544): Setting Network Configuration for NAT. 2024-02-13 17:06:48 (19544): Enabling VM Network Access. 2024-02-13 17:06:48 (19544): Disabling USB Support for VM. 2024-02-13 17:06:48 (19544): Disabling COM Port Support for VM. 2024-02-13 17:06:49 (19544): Disabling LPT Port Support for VM. 2024-02-13 17:06:49 (19544): Disabling Audio Support for VM. 2024-02-13 17:06:49 (19544): Disabling Clipboard Support for VM. 2024-02-13 17:06:49 (19544): Disabling Drag and Drop Support for VM. 2024-02-13 17:06:50 (19544): Adding storage controller(s) to VM. 2024-02-13 17:06:50 (19544): Adding virtual disk drive to VM. (CMS_2022_09_07.vdi) 2024-02-13 17:06:53 (19544): Adding VirtualBox Guest Additions to VM. 2024-02-13 17:06:53 (19544): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-02-13 17:06:53 (19544): forwarding host port 63734 to guest port 80 2024-02-13 17:06:54 (19544): Enabling remote desktop for VM. 2024-02-13 17:06:54 (19544): Enabling shared directory for VM. 2024-02-13 17:06:56 (19544): Starting VM using VBoxManage interface. (boinc_a0b23db1659f4505, slot#8) 2024-02-13 17:07:05 (19544): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_a0b23db1659f4505" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_a0b23db1659f4505" to power on... 2024-02-13 17:07:06 (19544): VM failed to start. 2024-02-13 17:07:06 (19544): Could not start 2024-02-13 17:07:06 (19544): ERROR: VM failed to start 2024-02-13 17:07:06 (19544): Powering off VM. 2024-02-13 17:07:06 (19544): Deregistering VM. (boinc_a0b23db1659f4505, slot#8) 2024-02-13 17:07:06 (19544): Removing network bandwidth throttle group from VM. 2024-02-13 17:07:06 (19544): Removing VM from VirtualBox. Hypervisor System Log: 00:00:10.351485 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.352309 Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.391199 Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" 00:00:10.391968 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:10.435196 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:10.625479 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:10.689007 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:10.887826 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.888805 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:10.913623 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:10.914002 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.917696 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:10.950903 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:10.951836 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:10.977994 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:11.157961 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.192600 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.192891 Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.233846 Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" 00:00:11.234403 Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.253120 Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" 00:00:11.253793 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:11.278068 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:11.433581 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:11.604880 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:11.710153 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:11.736751 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:12.284357 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:12.314799 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:12.556929 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:12.592321 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:13.252896 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0 00:00:13.281389 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.281552 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.796522 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.826327 Launched VM: 2075973760 pid: 596 (0x254) frontend: headless name: boinc_a0b23db1659f4505 00:00:23.652366 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:23.689556 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:23.831379 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:23.925796 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" with version "1.19-windows" 00:00:23.988952 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox" 00:00:24.209735 Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.248394 Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" 00:00:24.248656 Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.300776 Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" 00:00:24.302501 DeleteVM Saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.433669 DeleteVM Finished saving settings file "C:\Users\Dirk\.VirtualBox\VirtualBox.xml" 00:00:29.444135 main VirtualBox: object deletion starts 00:00:29.445609 main HostDnsMonitor: shutting down ... 00:00:29.445673 main HostDnsMonitor: shut down 00:00:29.448431 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:29.448729 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: VBoxManageDisk.cpp 2024-02-13 17:06:46 (19544): Command: VBoxManage -q createvm --name "boinc_a0b23db1659f4505" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_a0b23db1659f4505' is created and registered. UUID: c7a4b690-bae9-4fd6-861a-9c9f21351ae3 Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_a0b23db1659f4505\boinc_a0b23db1659f4505.vbox' 2024-02-13 17:06:46 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --description "CMS_2345296_1707782444.511479_0" Exit Code: 0 Output: 2024-02-13 17:06:46 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --memory 4584 Exit Code: 0 Output: 2024-02-13 17:06:47 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --cpus 4 Exit Code: 0 Output: 2024-02-13 17:06:47 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2024-02-13 17:06:47 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-02-13 17:06:48 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-02-13 17:06:48 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-02-13 17:06:48 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --cableconnected1 on Exit Code: 0 Output: 2024-02-13 17:06:48 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --usb off Exit Code: 0 Output: 2024-02-13 17:06:49 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --uart1 off --uart2 off Exit Code: 0 Output: 2024-02-13 17:06:49 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-02-13 17:06:49 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2024-02-13 17:06:49 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --clipboard disabled Exit Code: 0 Output: 2024-02-13 17:06:50 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --draganddrop disabled Exit Code: 0 Output: 2024-02-13 17:06:50 (19544): Command: VBoxManage -q storagectl "boinc_a0b23db1659f4505" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-02-13 17:06:50 (19544): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: UUID: 8fb925ef-3497-4bfb-88e3-bbab2930787f Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3854 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-02-13 17:06:51 (19544): Command: VBoxManage -q storageattach "boinc_a0b23db1659f4505" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2024-02-13 17:06:51 (19544): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2024-02-13 17:06:52 (19544): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: UUID: 8fb925ef-3497-4bfb-88e3-bbab2930787f Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2022_09_07.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3854 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-02-13 17:06:52 (19544): Command: VBoxManage -q storageattach "boinc_a0b23db1659f4505" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2024-02-13 17:06:53 (19544): Command: VBoxManage -q storageattach "boinc_a0b23db1659f4505" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2024-02-13 17:06:53 (19544): Command: VBoxManage -q storageattach "boinc_a0b23db1659f4505" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2022_09_07.vdi" Exit Code: 0 Output: 2024-02-13 17:06:53 (19544): Command: VBoxManage -q storageattach "boinc_a0b23db1659f4505" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-02-13 17:06:53 (19544): Command: VBoxManage -q bandwidthctl "boinc_a0b23db1659f4505" add "boinc_a0b23db1659f4505_net" --type network --limit 1024G Exit Code: 0 Output: 2024-02-13 17:06:54 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --natpf1 ",tcp,127.0.0.1,63734,,80" Exit Code: 0 Output: 2024-02-13 17:06:54 (19544): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 7.0.8 Revision: 156879 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: true Why unusable: 2024-02-13 17:06:54 (19544): Command: VBoxManage -q modifyvm "boinc_a0b23db1659f4505" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 63735 Exit Code: 0 Output: 2024-02-13 17:06:55 (19544): Command: VBoxManage -q sharedfolder add "boinc_a0b23db1659f4505" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared" Exit Code: 0 Output: 2024-02-13 17:07:05 (19544): Command: VBoxManage -q startvm "boinc_a0b23db1659f4505" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_a0b23db1659f4505" to power on... 2024-02-13 17:07:06 (19544): Command: VBoxManage -q snapshot "boinc_a0b23db1659f4505" list Exit Code: -108 Output: This machine does not have any snapshots 2024-02-13 17:07:06 (19544): Command: VBoxManage -q bandwidthctl "boinc_a0b23db1659f4505" remove "boinc_a0b23db1659f4505_net" Exit Code: 0 Output: 2024-02-13 17:07:06 (19544): Command: VBoxManage -q unregistervm "boinc_a0b23db1659f4505" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:07:12 (19544): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN