Name | CMS_2899719_1715039599.349806_0 |
Workunit | 2411586 |
Created | 6 May 2024, 23:53:22 UTC |
Sent | 7 May 2024, 20:39:53 UTC |
Report deadline | 14 May 2024, 20:39:53 UTC |
Received | 7 May 2024, 21:51:10 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 3823 |
Run time | 34 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.34 GFLOPS |
Application version | CMS Simulation v61.01 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 8.65 MB |
Peak swap size | 2.80 MB |
Peak disk usage | 1.90 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2024-05-07 14:47:05 (7108): vboxwrapper version 26207 2024-05-07 14:47:05 (7108): BOINC client version: 7.24.1 2024-05-07 14:47:06 (7108): VBoxManage version raw: 2024-05-07 14:47:09 (7108): Detected: VirtualBox VboxManage Interface (Version: Unknown) 2024-05-07 14:47:10 (7108): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-05-07 14:47:10 (7108): Successfully copied 'init_data.xml' to the shared directory. 2024-05-07 14:47:10 (7108): Create VM. (boinc_57e2bb5e24ce28af, slot#0) 2024-05-07 14:47:11 (7108): Setting Memory Size for VM. (2792MB) 2024-05-07 14:47:11 (7108): Setting CPU Count for VM. (2) 2024-05-07 14:47:12 (7108): Setting Chipset Options for VM. 2024-05-07 14:47:13 (7108): Setting Graphics Controller Options for VM. 2024-05-07 14:47:13 (7108): Setting Boot Options for VM. 2024-05-07 14:47:13 (7108): Setting Network Configuration for NAT. 2024-05-07 14:47:14 (7108): Enabling VM Network Access. 2024-05-07 14:47:14 (7108): Disabling USB Support for VM. 2024-05-07 14:47:14 (7108): Disabling COM Port Support for VM. 2024-05-07 14:47:15 (7108): Disabling LPT Port Support for VM. 2024-05-07 14:47:15 (7108): Disabling Audio Support for VM. 2024-05-07 14:47:15 (7108): Disabling Clipboard Support for VM. 2024-05-07 14:47:16 (7108): Disabling Drag and Drop Support for VM. 2024-05-07 14:47:16 (7108): Adding storage controller(s) to VM. 2024-05-07 14:47:16 (7108): Adding virtual disk drive to VM. (CMS_2024_04_26a_mt_dev.vdi) 2024-05-07 14:47:18 (7108): Adding VirtualBox Guest Additions to VM. 2024-05-07 14:47:19 (7108): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-05-07 14:47:19 (7108): forwarding host port 63996 to guest port 80 2024-05-07 14:47:20 (7108): Enabling remote desktop for VM. 2024-05-07 14:47:20 (7108): Required extension pack not installed, remote desktop not enabled. 2024-05-07 14:47:20 (7108): Enabling shared directory for VM. 2024-05-07 14:47:21 (7108): Starting VM using VBoxManage interface. (boinc_57e2bb5e24ce28af, slot#0) 2024-05-07 14:47:30 (7108): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_57e2bb5e24ce28af" --type headless Output: VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_57e2bb5e24ce28af" to power on... 2024-05-07 14:47:30 (7108): VM failed to start. 2024-05-07 14:47:30 (7108): Could not start 2024-05-07 14:47:30 (7108): ERROR: VM failed to start 2024-05-07 14:47:30 (7108): Powering off VM. 2024-05-07 14:47:30 (7108): Deregistering VM. (boinc_57e2bb5e24ce28af, slot#0) 2024-05-07 14:47:30 (7108): Removing network bandwidth throttle group from VM. 2024-05-07 14:47:30 (7108): Removing VM from VirtualBox. Hypervisor System Log: 00:00:12.027621 Saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.058821 Finished saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" 00:00:12.058821 Saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" with version "1.19-windows" 00:00:12.105621 Finished saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" 00:00:12.464421 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.464421 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.480022 Saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" with version "1.19-windows" 00:00:12.651622 Finished saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" 00:00:12.994822 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.994822 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.010422 Saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" with version "1.19-windows" 00:00:13.104023 Finished saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" 00:00:13.790424 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.790424 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.806024 Saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" with version "1.19-windows" 00:00:13.868424 Finished saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" 00:00:14.305225 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.305225 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.320825 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:14.336425 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.336425 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.367625 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.570425 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.570425 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.726425 Launched VM: 60816384 pid: 1332 (0x534) frontend: headless name: boinc_57e2bb5e24ce28af 00:00:23.474412 Saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" with version "1.19-windows" 00:00:23.538420 Finished saving settings file "D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox" 00:00:23.755948 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:23.755948 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:23.761948 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:23.965474 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:23.965474 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:24.227478 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:24.227478 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:24.227478 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:24.227478 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:24.227478 Saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.274278 Finished saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" 00:00:24.274278 Saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.289878 Finished saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" 00:00:24.289878 DeleteVM Saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.336678 DeleteVM Finished saving settings file "C:\Users\Bri\.VirtualBox\VirtualBox.xml" 00:00:29.359887 main VirtualBox: object deletion starts 00:00:29.359887 main HostDnsMonitor: shutting down ... 00:00:29.359887 main HostDnsMonitor: shut down 00:00:29.359887 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:29.359887 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: VM encryption ExtPack: Log history count: 3 Default frontend: Default audio driver: Windows Audio Session Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: User language: C 2024-05-07 14:47:10 (7108): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2024-05-07T21:47:09.959000000Z Processor online count: 4 Processor count: 4 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor supports virt. vmsave/vmload: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5 CPU M 520 @ 2.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5 CPU M 520 @ 2.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5 CPU M 520 @ 2.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5 CPU M 520 @ 2.40GHz Memory size: 6004 MByte Memory available: 3386 MByte Operating system: Windows 7 Operating system version: 6.1.7601sp1 2024-05-07 14:47:10 (7108): Command: VBoxManage -q showvminfo "boinc_57e2bb5e24ce28af" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_57e2bb5e24ce28af' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp 2024-05-07 14:47:10 (7108): Command: VBoxManage -q createvm --name "boinc_57e2bb5e24ce28af" --basefolder "D:\BOINC folders\BOINC data\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_57e2bb5e24ce28af' is created and registered. UUID: 5bd35e82-b92b-4108-9349-1ce4e5f587b0 Settings file: 'D:\BOINC folders\BOINC data\slots\0\boinc_57e2bb5e24ce28af\boinc_57e2bb5e24ce28af.vbox' 2024-05-07 14:47:11 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --description "CMS_2899719_1715039599.349806_0" Exit Code: 0 Output: 2024-05-07 14:47:11 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --memory 2792 Exit Code: 0 Output: 2024-05-07 14:47:12 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --cpus 2 Exit Code: 0 Output: 2024-05-07 14:47:13 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2024-05-07 14:47:13 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-05-07 14:47:13 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-05-07 14:47:14 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-05-07 14:47:14 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --cableconnected1 on Exit Code: 0 Output: 2024-05-07 14:47:14 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --usb off Exit Code: 0 Output: 2024-05-07 14:47:15 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --uart1 off --uart2 off Exit Code: 0 Output: 2024-05-07 14:47:15 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-05-07 14:47:15 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --audio-enabled off Exit Code: 0 Output: 2024-05-07 14:47:16 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --clipboard disabled Exit Code: 0 Output: 2024-05-07 14:47:16 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --draganddrop disabled Exit Code: 0 Output: 2024-05-07 14:47:16 (7108): Command: VBoxManage -q storagectl "boinc_57e2bb5e24ce28af" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-05-07 14:47:17 (7108): Command: VBoxManage -q showhdinfo "D:\BOINC folders\BOINC data/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2024_04_26a_mt_dev.vdi" Exit Code: 0 Output: UUID: f72d102d-2183-403a-9ce8-1b510d818a36 Parent UUID: base State: created Type: normal (base) Location: D:\BOINC folders\BOINC data\projects\lhcathomedev.cern.ch_lhcathome-dev\CMS_2024_04_26a_mt_dev.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-05-07 14:47:17 (7108): Command: VBoxManage -q storageattach "boinc_57e2bb5e24ce28af" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "D:\BOINC folders\BOINC data/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2024_04_26a_mt_dev.vdi" Exit Code: 0 Output: 2024-05-07 14:47:18 (7108): Command: VBoxManage -q storageattach "boinc_57e2bb5e24ce28af" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2024-05-07 14:47:18 (7108): Command: VBoxManage -q storageattach "boinc_57e2bb5e24ce28af" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "D:\BOINC folders\BOINC data/projects/lhcathomedev.cern.ch_lhcathome-dev/CMS_2024_04_26a_mt_dev.vdi" Exit Code: 0 Output: 2024-05-07 14:47:19 (7108): Command: VBoxManage -q storageattach "boinc_57e2bb5e24ce28af" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-05-07 14:47:19 (7108): Command: VBoxManage -q bandwidthctl "boinc_57e2bb5e24ce28af" add "boinc_57e2bb5e24ce28af_net" --type network --limit 1024G Exit Code: 0 Output: 2024-05-07 14:47:20 (7108): Command: VBoxManage -q modifyvm "boinc_57e2bb5e24ce28af" --natpf1 ",tcp,127.0.0.1,63996,,80" Exit Code: 0 Output: 2024-05-07 14:47:20 (7108): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2024-05-07 14:47:21 (7108): Command: VBoxManage -q sharedfolder add "boinc_57e2bb5e24ce28af" --name "shared" --hostpath "D:\BOINC folders\BOINC data\slots\0/shared" Exit Code: 0 Output: 2024-05-07 14:47:30 (7108): Command: VBoxManage -q startvm "boinc_57e2bb5e24ce28af" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_57e2bb5e24ce28af" to power on... 2024-05-07 14:47:30 (7108): Command: VBoxManage -q snapshot "boinc_57e2bb5e24ce28af" list Exit Code: -108 Output: This machine does not have any snapshots 2024-05-07 14:47:30 (7108): Command: VBoxManage -q bandwidthctl "boinc_57e2bb5e24ce28af" remove "boinc_57e2bb5e24ce28af_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2024-05-07 14:47:31 (7108): Command: VBoxManage -q unregistervm "boinc_57e2bb5e24ce28af" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2024-05-07 14:47:36 (7108): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN