Name CMS_3725064_1724640154.340243_0
Workunit 2443437
Created 26 Aug 2024, 2:42:36 UTC
Sent 4 Sep 2024, 0:46:02 UTC
Report deadline 11 Sep 2024, 0:46:02 UTC
Received 6 Sep 2024, 7:03:09 UTC
Server state Over
Outcome Success
Client state Done
Exit status 0 (0x00000000)
Computer ID 5107
Run time 1 hours 19 min 4 sec
CPU time 3 hours 16 min 10 sec
Validate state Valid
Credit 130.03
Device peak FLOPS 12.06 GFLOPS
Application version CMS Simulation v61.01 (vbox64_mt_mcore_cms)
windows_x86_64
Peak working set size 78.34 MB
Peak swap size 82.95 MB
Peak disk usage 1.38 GB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<stderr_txt>
2024-09-05 16:33:02 (7820): vboxwrapper version 26207
2024-09-05 16:33:02 (7820): BOINC client version: 8.0.2
2024-09-05 16:33:02 (7820): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2024-09-05 16:33:03 (7820): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-09-05 16:33:03 (7820): Successfully copied 'init_data.xml' to the shared directory.
2024-09-05 16:33:03 (7820): Create VM. (boinc_ebd237b10bf81b05, slot#17)
2024-09-05 16:33:03 (7820): Setting Memory Size for VM. (4584MB)
2024-09-05 16:33:04 (7820): Setting CPU Count for VM. (4)
2024-09-05 16:33:04 (7820): Setting Chipset Options for VM.
2024-09-05 16:33:04 (7820): Setting Graphics Controller Options for VM.
2024-09-05 16:33:04 (7820): Setting Boot Options for VM.
2024-09-05 16:33:05 (7820): Setting Network Configuration for NAT.
2024-09-05 16:33:05 (7820): Enabling VM Network Access.
2024-09-05 16:33:05 (7820): Disabling USB Support for VM.
2024-09-05 16:33:06 (7820): Disabling COM Port Support for VM.
2024-09-05 16:33:06 (7820): Disabling LPT Port Support for VM.
2024-09-05 16:33:07 (7820): Disabling Audio Support for VM.
2024-09-05 16:33:07 (7820): Disabling Clipboard Support for VM.
2024-09-05 16:33:08 (7820): Disabling Drag and Drop Support for VM.
2024-09-05 16:33:08 (7820): Adding storage controller(s) to VM.
2024-09-05 16:33:09 (7820): Adding virtual disk drive to VM. (CMS_2024_04_26a_mt_dev.vdi)
2024-09-05 16:33:10 (7820): Adding VirtualBox Guest Additions to VM.
2024-09-05 16:33:10 (7820): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2024-09-05 16:33:11 (7820): forwarding host port 37057 to guest port 80
2024-09-05 16:33:12 (7820): Enabling remote desktop for VM.
2024-09-05 16:33:12 (7820): Required extension pack not installed, remote desktop not enabled.
2024-09-05 16:33:12 (7820): Enabling shared directory for VM.
2024-09-05 16:33:13 (7820): Starting VM using VBoxManage interface. (boinc_ebd237b10bf81b05, slot#17)
2024-09-05 16:33:25 (7820): Successfully started VM. (PID = '4980')
2024-09-05 16:33:25 (7820): Reporting VM Process ID to BOINC.
2024-09-05 16:33:25 (7820): Guest Log: BIOS: VirtualBox 7.0.6
2024-09-05 16:33:25 (7820): Guest Log: CPUID EDX: 0x178bfbff
2024-09-05 16:33:25 (7820): Guest Log: BIOS: No PCI IDE controller, not probing IDE
2024-09-05 16:33:25 (7820): Guest Log: BIOS: AHCI 0-P#0: PCHS=16383/16/63 LCHS=1024/255/63 0x0000000002800000 sectors
2024-09-05 16:33:25 (7820): VM state change detected. (old = 'poweredoff', new = 'running')
2024-09-05 16:33:25 (7820): Detected: Web Application Enabled (http://localhost:37057)
2024-09-05 16:33:25 (7820): Preference change detected
2024-09-05 16:33:25 (7820): Setting CPU throttle for VM. (90%)
2024-09-05 16:33:25 (7820): Setting checkpoint interval to 600 seconds. (Higher value of (Preference: 60 seconds) or (Vbox_job.xml: 600 seconds))
2024-09-05 16:33:27 (7820): Guest Log: BIOS: Boot : bseqnr=1, bootseq=0032
2024-09-05 16:33:27 (7820): Guest Log: BIOS: Booting from Hard Disk...
2024-09-05 16:33:34 (7820): Guest Log: BIOS: KBD: unsupported int 16h function 03
2024-09-05 16:33:34 (7820): Guest Log: BIOS: AX=0305 BX=0000 CX=0000 DX=0000 
2024-09-05 16:34:39 (7820): Guest Log: vgdrvHeartbeatInit: Setting up heartbeat to trigger every 2000 milliseconds
2024-09-05 16:34:39 (7820): Guest Log: vboxguest: misc device minor 56, IRQ 20, I/O port d020, MMIO at 00000000f0400000 (size 0x400000)
2024-09-05 16:34:44 (7820): Guest Log: VBoxService 5.2.6 r120293 (verbosity: 0) linux.amd64 (Jan 15 2018 14:51:00) release log
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.000822 main     Log opened 2024-09-05T06:34:44.595645000Z
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.003788 main     OS Product: Linux
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.004418 main     OS Release: 4.14.232-19.cernvm.x86_64
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.004705 main     OS Version: #1 SMP Fri Apr 30 17:12:25 CEST 2021
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.004809 main     Executable: /usr/sbin/VBoxService
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.004811 main     Process ID: 2281
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.004813 main     Package type: LINUX_64BITS_GENERIC
2024-09-05 16:34:44 (7820): Guest Log: 00:00:00.013840 main     5.2.6 r120293 started. Verbose level = 0
2024-09-05 16:35:50 (7820): Guest Log: [INFO] Mounting the shared directory
2024-09-05 16:35:50 (7820): Guest Log: [INFO] Shared directory mounted, enabling vboxmonitor
2024-09-05 16:35:51 (7820): Guest Log: [INFO] Sourcing essential functions from /cvmfs/grid.cern.ch
2024-09-05 16:35:52 (7820): Guest Log: [INFO] Testing connection to cern.ch
2024-09-05 16:35:53 (7820): Guest Log: [INFO] Testing connection to VCCS
2024-09-05 16:35:54 (7820): Guest Log: [INFO] Testing connection to HTCondor
2024-09-05 16:35:56 (7820): Guest Log: [INFO] Testing connection to WMAgent
2024-09-05 16:35:57 (7820): Guest Log: [INFO] Testing connection to EOSCMS
2024-09-05 16:35:58 (7820): Guest Log: [INFO] Testing connection to CMS-Factory
2024-09-05 16:35:59 (7820): Guest Log: [INFO] Testing connection to CMS-Frontier
2024-09-05 16:36:00 (7820): Guest Log: [INFO] Testing connection to Frontier
2024-09-05 16:36:02 (7820): Guest Log: [INFO] Could not find a local HTTP proxy
2024-09-05 16:36:03 (7820): Guest Log: [INFO] CVMFS and Frontier will have to use DIRECT connections
2024-09-05 16:36:03 (7820): Guest Log: [INFO] This makes the application less efficient
2024-09-05 16:36:03 (7820): Guest Log: [INFO] It also puts higher load on the project servers
2024-09-05 16:36:04 (7820): Guest Log: [INFO] Setting up a local HTTP proxy is highly recommended
2024-09-05 16:36:04 (7820): Guest Log: [INFO] Advice can be found in the project forum
2024-09-05 16:36:06 (7820): Guest Log: [INFO] Reloading and probing the CVMFS configuration
2024-09-05 16:36:26 (7820): Guest Log: [INFO] Probing /cvmfs/grid.cern.ch... OK
2024-09-05 16:36:33 (7820): Guest Log: [INFO] Probing /cvmfs/oasis.opensciencegrid.org... OK
2024-09-05 16:36:33 (7820): Guest Log: [INFO] Probing /cvmfs/singularity.opensciencegrid.org... OK
2024-09-05 16:36:34 (7820): Guest Log: [INFO] Probing /cvmfs/cms.cern.ch... OK
2024-09-05 16:36:35 (7820): Guest Log: [INFO] Probing /cvmfs/cms-ib.cern.ch... OK
2024-09-05 16:36:37 (7820): Guest Log: [INFO] Excerpt from "cvmfs_config stat": VERSION HOST PROXY
2024-09-05 16:36:37 (7820): Guest Log: [INFO] 2.7.2.0 http://s1cern-cvmfs.openhtc.io DIRECT
2024-09-05 16:36:37 (7820): Guest Log: [INFO] Environment HTTP proxy: not set
2024-09-05 16:36:38 (7820): Guest Log: [INFO] Reading volunteer information
2024-09-05 16:37:24 (7820): Guest Log: [INFO] Requesting an X509 credential from LHC@home
2024-09-05 16:37:32 (7820): Guest Log: [INFO] Requesting an X509 credential from vLHC@home-dev
2024-09-05 16:37:35 (7820): Guest Log: [INFO] Requesting an idtoken from LHC@home
2024-09-05 16:37:37 (7820): Guest Log: [INFO] Requesting an idtoken from vLHC@home-dev
2024-09-05 16:37:40 (7820): Guest Log: [INFO] CMS application starting. Check log files.
2024-09-05 16:50:55 (8976): vboxwrapper version 26207
2024-09-05 16:50:55 (8976): BOINC client version: 8.0.2
2024-09-05 16:50:57 (8976): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2024-09-05 16:50:57 (8976): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-09-05 16:50:58 (8976): Guest Log: BIOS: VirtualBox 7.0.6
2024-09-05 16:50:58 (8976): Guest Log: CPUID EDX: 0x178bfbff
2024-09-05 16:50:58 (8976): Guest Log: BIOS: No PCI IDE controller, not probing IDE
2024-09-05 16:50:58 (8976): Guest Log: BIOS: AHCI 0-P#0: PCHS=16383/16/63 LCHS=1024/255/63 0x0000000002800000 sectors
2024-09-05 16:50:58 (8976): Guest Log: BIOS: Boot : bseqnr=1, bootseq=0032
2024-09-05 16:50:58 (8976): Guest Log: BIOS: Booting from Hard Disk...
2024-09-05 16:50:58 (8976): Guest Log: BIOS: KBD: unsupported int 16h function 03
2024-09-05 16:50:58 (8976): Guest Log: BIOS: AX=0305 BX=0000 CX=0000 DX=0000 
2024-09-05 16:50:58 (8976): Guest Log: vgdrvHeartbeatInit: Setting up heartbeat to trigger every 2000 milliseconds
2024-09-05 16:50:58 (8976): Guest Log: vboxguest: misc device minor 56, IRQ 20, I/O port d020, MMIO at 00000000f0400000 (size 0x400000)
2024-09-05 16:50:58 (8976): Guest Log: VBoxService 5.2.6 r120293 (verbosity: 0) linux.amd64 (Jan 15 2018 14:51:00) release log
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.000822 main     Log opened 2024-09-05T06:34:44.595645000Z
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.003788 main     OS Product: Linux
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.004418 main     OS Release: 4.14.232-19.cernvm.x86_64
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.004705 main     OS Version: #1 SMP Fri Apr 30 17:12:25 CEST 2021
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.004809 main     Executable: /usr/sbin/VBoxService
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.004811 main     Process ID: 2281
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.004813 main     Package type: LINUX_64BITS_GENERIC
2024-09-05 16:50:58 (8976): Guest Log: 00:00:00.013840 main     5.2.6 r120293 started. Verbose level = 0
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Mounting the shared directory
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Shared directory mounted, enabling vboxmonitor
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Sourcing essential functions from /cvmfs/grid.cern.ch
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to cern.ch
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to VCCS
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to HTCondor
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to WMAgent
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to EOSCMS
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to CMS-Factory
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to CMS-Frontier
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Testing connection to Frontier
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Could not find a local HTTP proxy
2024-09-05 16:50:58 (8976): Guest Log: [INFO] CVMFS and Frontier will have to use DIRECT connections
2024-09-05 16:50:58 (8976): Guest Log: [INFO] This makes the application less efficient
2024-09-05 16:50:58 (8976): Guest Log: [INFO] It also puts higher load on the project servers
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Setting up a local HTTP proxy is highly recommended
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Advice can be found in the project forum
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Reloading and probing the CVMFS configuration
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Probing /cvmfs/grid.cern.ch... OK
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Probing /cvmfs/oasis.opensciencegrid.org... OK
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Probing /cvmfs/singularity.opensciencegrid.org... OK
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Probing /cvmfs/cms.cern.ch... OK
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Probing /cvmfs/cms-ib.cern.ch... OK
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Excerpt from "cvmfs_config stat": VERSION HOST PROXY
2024-09-05 16:50:58 (8976): Guest Log: [INFO] 2.7.2.0 http://s1cern-cvmfs.openhtc.io DIRECT
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Environment HTTP proxy: not set
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Reading volunteer information
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Requesting an X509 credential from LHC@home
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Requesting an X509 credential from vLHC@home-dev
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Requesting an idtoken from LHC@home
2024-09-05 16:50:58 (8976): Guest Log: [INFO] Requesting an idtoken from vLHC@home-dev
2024-09-05 16:50:58 (8976): Guest Log: [INFO] CMS application starting. Check log files.
2024-09-05 16:50:58 (8976): Starting VM using VBoxManage interface. (boinc_ebd237b10bf81b05, slot#17)
2024-09-05 16:51:09 (8976): Successfully started VM. (PID = '6260')
2024-09-05 16:51:09 (8976): Reporting VM Process ID to BOINC.
2024-09-05 16:51:09 (8976): Guest Log: BIOS: VirtualBox 7.0.6
2024-09-05 16:51:09 (8976): Guest Log: CPUID EDX: 0x178bfbff
2024-09-05 16:51:09 (8976): Guest Log: BIOS: No PCI IDE controller, not probing IDE
2024-09-05 16:51:09 (8976): Guest Log: BIOS: AHCI 0-P#0: PCHS=16383/16/63 LCHS=1024/255/63 0x0000000002800000 sectors
2024-09-05 16:51:09 (8976): VM state change detected. (old = 'poweredoff', new = 'running')
2024-09-05 16:51:09 (8976): Detected: Web Application Enabled (http://localhost:37057)
2024-09-05 16:51:09 (8976): Preference change detected
2024-09-05 16:51:09 (8976): Setting CPU throttle for VM. (90%)
2024-09-05 16:51:10 (8976): Setting checkpoint interval to 600 seconds. (Higher value of (Preference: 60 seconds) or (Vbox_job.xml: 600 seconds))
2024-09-05 16:51:11 (8976): Guest Log: BIOS: Boot : bseqnr=1, bootseq=0032
2024-09-05 16:51:11 (8976): Guest Log: BIOS: Booting from Hard Disk...
2024-09-05 16:51:14 (8976): Guest Log: BIOS: KBD: unsupported int 16h function 03
2024-09-05 16:51:14 (8976): Guest Log: BIOS: AX=0305 BX=0000 CX=0000 DX=0000 
2024-09-05 16:52:11 (8976): Guest Log: vgdrvHeartbeatInit: Setting up heartbeat to trigger every 2000 milliseconds
2024-09-05 16:52:11 (8976): Guest Log: vboxguest: misc device minor 56, IRQ 20, I/O port d020, MMIO at 00000000f0400000 (size 0x400000)
2024-09-05 16:52:13 (8976): Guest Log: VBoxService 5.2.6 r120293 (verbosity: 0) linux.amd64 (Jan 15 2018 14:51:00) release log
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.000286 main     Log opened 2024-09-05T06:52:13.919036000Z
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.000858 main     OS Product: Linux
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.001113 main     OS Release: 4.14.232-19.cernvm.x86_64
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.001204 main     OS Version: #1 SMP Fri Apr 30 17:12:25 CEST 2021
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.001308 main     Executable: /usr/sbin/VBoxService
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.001310 main     Process ID: 2284
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.001311 main     Package type: LINUX_64BITS_GENERIC
2024-09-05 16:52:13 (8976): Guest Log: 00:00:00.005370 main     5.2.6 r120293 started. Verbose level = 0
2024-09-05 16:52:50 (8976): Guest Log: [INFO] Mounting the shared directory
2024-09-05 16:52:50 (8976): Guest Log: [INFO] Shared directory mounted, enabling vboxmonitor
2024-09-05 16:52:51 (8976): Guest Log: [INFO] Sourcing essential functions from /cvmfs/grid.cern.ch
2024-09-05 16:52:51 (8976): Guest Log: [INFO] Testing connection to cern.ch
2024-09-05 16:52:52 (8976): Guest Log: [INFO] Testing connection to VCCS
2024-09-05 16:52:53 (8976): Guest Log: [INFO] Testing connection to HTCondor
2024-09-05 16:52:54 (8976): Guest Log: [INFO] Testing connection to WMAgent
2024-09-05 16:52:55 (8976): Guest Log: [INFO] Testing connection to EOSCMS
2024-09-05 16:52:56 (8976): Guest Log: [INFO] Testing connection to CMS-Factory
2024-09-05 16:52:57 (8976): Guest Log: [INFO] Testing connection to CMS-Frontier
2024-09-05 16:52:57 (8976): Guest Log: [INFO] Testing connection to Frontier
2024-09-05 16:53:01 (8976): Guest Log: [INFO] Could not find a local HTTP proxy
2024-09-05 16:53:01 (8976): Guest Log: [INFO] CVMFS and Frontier will have to use DIRECT connections
2024-09-05 16:53:01 (8976): Guest Log: [INFO] This makes the application less efficient
2024-09-05 16:53:01 (8976): Guest Log: [INFO] It also puts higher load on the project servers
2024-09-05 16:53:02 (8976): Guest Log: [INFO] Setting up a local HTTP proxy is highly recommended
2024-09-05 16:53:02 (8976): Guest Log: [INFO] Advice can be found in the project forum
2024-09-05 16:53:02 (8976): Guest Log: [INFO] Reloading and probing the CVMFS configuration
2024-09-05 16:53:13 (8976): Guest Log: [INFO] Probing /cvmfs/grid.cern.ch... OK
2024-09-05 16:53:20 (8976): Guest Log: [INFO] Probing /cvmfs/cms.cern.ch... OK
2024-09-05 16:53:20 (8976): Guest Log: [INFO] Probing /cvmfs/singularity.opensciencegrid.org... OK
2024-09-05 16:53:20 (8976): Guest Log: [INFO] Probing /cvmfs/oasis.opensciencegrid.org... OK
2024-09-05 16:53:21 (8976): Guest Log: [INFO] Probing /cvmfs/cms-ib.cern.ch... OK
2024-09-05 16:53:23 (8976): Guest Log: [INFO] Excerpt from "cvmfs_config stat": VERSION HOST PROXY
2024-09-05 16:53:23 (8976): Guest Log: [INFO] 2.7.2.0 http://s1swinburne-cvmfs.openhtc.io:8080 DIRECT
2024-09-05 16:53:23 (8976): Guest Log: [INFO] Environment HTTP proxy: not set
2024-09-05 16:53:24 (8976): Guest Log: [INFO] Reading volunteer information
2024-09-05 16:53:26 (8976): Guest Log: [INFO] Requesting an X509 credential from LHC@home
2024-09-05 16:53:29 (8976): Guest Log: [INFO] Requesting an X509 credential from vLHC@home-dev
2024-09-05 16:53:32 (8976): Guest Log: [INFO] Requesting an idtoken from LHC@home
2024-09-05 16:53:35 (8976): Guest Log: [INFO] Requesting an idtoken from vLHC@home-dev
2024-09-05 16:53:37 (8976): Guest Log: [INFO] CMS application starting. Check log files.
2024-09-05 17:58:14 (8976): Stopping VM.
2024-09-05 17:59:00 (8976): Error in stop VM for VM: -182
Command:
VBoxManage -q controlvm "boinc_ebd237b10bf81b05" savestate
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...
2024-09-05 17:59:00 (8976): VM did not stop when requested.
2024-09-05 17:59:00 (8976): VM was NOT successfully terminated.
2024-09-06 17:01:41 (3856): vboxwrapper version 26207
2024-09-06 17:01:41 (3856): BOINC client version: 8.0.2
2024-09-06 17:01:44 (3856): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2024-09-06 17:01:44 (3856): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-09-06 17:01:45 (3856): Guest Log: BIOS: VirtualBox 7.0.6
2024-09-06 17:01:45 (3856): Guest Log: CPUID EDX: 0x178bfbff
2024-09-06 17:01:45 (3856): Guest Log: BIOS: No PCI IDE controller, not probing IDE
2024-09-06 17:01:45 (3856): Guest Log: BIOS: AHCI 0-P#0: PCHS=16383/16/63 LCHS=1024/255/63 0x0000000002800000 sectors
2024-09-06 17:01:45 (3856): Guest Log: BIOS: Boot : bseqnr=1, bootseq=0032
2024-09-06 17:01:45 (3856): Guest Log: BIOS: Booting from Hard Disk...
2024-09-06 17:01:45 (3856): Guest Log: BIOS: KBD: unsupported int 16h function 03
2024-09-06 17:01:45 (3856): Guest Log: BIOS: AX=0305 BX=0000 CX=0000 DX=0000 
2024-09-06 17:01:45 (3856): Guest Log: vgdrvHeartbeatInit: Setting up heartbeat to trigger every 2000 milliseconds
2024-09-06 17:01:45 (3856): Guest Log: vboxguest: misc device minor 56, IRQ 20, I/O port d020, MMIO at 00000000f0400000 (size 0x400000)
2024-09-06 17:01:45 (3856): Guest Log: VBoxService 5.2.6 r120293 (verbosity: 0) linux.amd64 (Jan 15 2018 14:51:00) release log
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.000286 main     Log opened 2024-09-05T06:52:13.919036000Z
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.000858 main     OS Product: Linux
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.001113 main     OS Release: 4.14.232-19.cernvm.x86_64
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.001204 main     OS Version: #1 SMP Fri Apr 30 17:12:25 CEST 2021
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.001308 main     Executable: /usr/sbin/VBoxService
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.001310 main     Process ID: 2284
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.001311 main     Package type: LINUX_64BITS_GENERIC
2024-09-06 17:01:45 (3856): Guest Log: 00:00:00.005370 main     5.2.6 r120293 started. Verbose level = 0
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Mounting the shared directory
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Shared directory mounted, enabling vboxmonitor
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Sourcing essential functions from /cvmfs/grid.cern.ch
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to cern.ch
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to VCCS
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to HTCondor
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to WMAgent
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to EOSCMS
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to CMS-Factory
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to CMS-Frontier
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Testing connection to Frontier
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Could not find a local HTTP proxy
2024-09-06 17:01:45 (3856): Guest Log: [INFO] CVMFS and Frontier will have to use DIRECT connections
2024-09-06 17:01:45 (3856): Guest Log: [INFO] This makes the application less efficient
2024-09-06 17:01:45 (3856): Guest Log: [INFO] It also puts higher load on the project servers
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Setting up a local HTTP proxy is highly recommended
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Advice can be found in the project forum
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Reloading and probing the CVMFS configuration
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Probing /cvmfs/grid.cern.ch... OK
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Probing /cvmfs/cms.cern.ch... OK
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Probing /cvmfs/singularity.opensciencegrid.org... OK
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Probing /cvmfs/oasis.opensciencegrid.org... OK
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Probing /cvmfs/cms-ib.cern.ch... OK
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Excerpt from "cvmfs_config stat": VERSION HOST PROXY
2024-09-06 17:01:45 (3856): Guest Log: [INFO] 2.7.2.0 http://s1swinburne-cvmfs.openhtc.io:8080 DIRECT
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Environment HTTP proxy: not set
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Reading volunteer information
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Requesting an X509 credential from LHC@home
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Requesting an X509 credential from vLHC@home-dev
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Requesting an idtoken from LHC@home
2024-09-06 17:01:45 (3856): Guest Log: [INFO] Requesting an idtoken from vLHC@home-dev
2024-09-06 17:01:45 (3856): Guest Log: [INFO] CMS application starting. Check log files.
2024-09-06 17:01:45 (3856): Starting VM using VBoxManage interface. (boinc_ebd237b10bf81b05, slot#17)
2024-09-06 17:02:18 (3856): Successfully started VM. (PID = '15240')
2024-09-06 17:02:18 (3856): Reporting VM Process ID to BOINC.
2024-09-06 17:02:18 (3856): VM state change detected. (old = 'poweredoff', new = 'running')
2024-09-06 17:02:18 (3856): Detected: Web Application Enabled (http://localhost:37057)
2024-09-06 17:02:18 (3856): Preference change detected
2024-09-06 17:02:18 (3856): Setting CPU throttle for VM. (90%)
2024-09-06 17:02:19 (3856): Setting checkpoint interval to 600 seconds. (Higher value of (Preference: 60 seconds) or (Vbox_job.xml: 600 seconds))
2024-09-06 17:02:19 (3856): Guest Log: 01:06:01.969181 timesync vgsvcTimeSyncWorker: Radical host time change: 83 053 445 000 000ns (HostNow=1 725 606 139 331 000 000 ns HostLast=1 725 523 085 886 000 000 ns)
2024-09-06 17:02:26 (3856): Guest Log: [INFO] glidein exited with return value 0.
2024-09-06 17:02:26 (3856): Guest Log: [INFO] Shutting Down.
2024-09-06 17:02:26 (3856): VM Completion File Detected.
2024-09-06 17:02:26 (3856): VM Completion Message: glidein exited with return value 0.
.
2024-09-06 17:02:26 (3856): Powering off VM.
2024-09-06 17:02:28 (3856): Successfully stopped VM.
2024-09-06 17:02:28 (3856): Deregistering VM. (boinc_ebd237b10bf81b05, slot#17)
2024-09-06 17:02:28 (3856): Removing network bandwidth throttle group from VM.
2024-09-06 17:02:28 (3856): Removing VM from VirtualBox.
2024-09-06 17:02:34 (3856): called boinc_finish(0)

</stderr_txt>
]]>


©2024 CERN